Gyanpur, Sant Ravidas Nagar, Uttar Pradesh
GST No. 09CKTPP4976P1ZO
Approx. Rs 15,500 / PieceGet Latest Price
Product BrochureService Details:Material | Stainless Steel |
Application Media | Water |
Brand | Enviroempirical |
Usage/Application | Automotive |
Operating Temperature | 150 |
Accuracy | 0.5% |
Display Type | Flange |
Approx. Rs 3.5 Lakh / PieceGet Latest Price
Product BrochureService Details:Type | Digital |
Model Name/Number | EES-WA-01 |
Brand | Enviroempirical |
Usage/Application | ETP SPT |
Material | Stainless Steel |
Frequency | 1 |
Online Effluent Water Quality Monitoring
Make: Enviro Empirical Model No: EES-WA-01
Parameters:
· BOD
· COD
· TSS
· PH
Specifications:
TSS (UV Based Probe)
· Standard Range: 0-500 mg
· Accuracy: +/- 5%
Ø Cod By Uv Correlation
· Standard Range: 0-1000 Mg/L
· CodAccuracy: +/- 5%
Ø Bod By Uv Correlation
· Standard Range: 0-1000 Mg/L Bod
· Accuracy: +/- 2%
Ø Ph (ion Exchange) Standard Range: 0-14 Ph Accuracy: +/- 2%
Approx. Rs 18,500 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Model Name/Number | EMAG-MS-01 |
Brand | ENVIRO EMPIRICAL |
Application Media | Water |
Usage/Application | Water |
Connection | FLANGE |
Display | Digital |
Flow Range | 17M3/HR TO 170M3/HR |
Accuracy | 0.5% |
Flange Size | 25MM |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Additional Information:
Approx. Rs 17,500 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Model Name/Number | EMAG-MS-01 |
Brand | ENVIRO EMPIRICAL |
Application Media | Water |
Usage/Application | Water |
Connection | FLANGE |
Display | Digital |
Flow Range | 17M3/HR TO 170M3/HR |
Accuracy | 0.5% |
Flange Size | 25MM |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Additional Information:
Approx. Rs 65,000 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Plastic Body |
Usage/Application | Automotive |
Model Name/Number | NA |
Flow Media Type | Water |
Flow Range | NA |
Application Media | WATER |
Display | Digital |
Color | BLUE |
Size | 15MM TO 1200MM |
Doppler clamp-on flow meters utilize the Doppler Effect to measure fluid flow. These work by transmitting ultrasonic waves into the fluid, which are then reflected back to the sensor by particles or bubbles in the flowing fluid. The frequency change between the transmitted and received waves is used to calculate the flow velocity.
Additional Information:
Approx. Rs 18,500 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Model Name/Number | EMAG-MS-01 |
Application Media | Water |
Brand | ENVIRO EMPIRICAL |
Connection | FLANGE END |
Display | Digital |
Flow Range | 17M3/HR TO 170M3/HR |
Accuracy | 0.5% |
Flange Size | 25MM |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Additional Information:
Approx. Rs 16,500 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Model Name/Number | EMAG-MS-01 |
Application Media | Water |
Brand | ENVIRO EMPIRICAL |
Usage/Application | Water |
Connection | FLANGE |
Display | Digital |
Flow Range | 17M3/HR TO 170M3/HR |
Accuracy | 0.5% |
Flange Size | 25MM |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Additional Information:
Approx. Rs 3 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Color | White |
Usage/Application | ETP STP |
Packaging Size | BOX |
Brand/Make | ENVIRO EMPIRICAL |
Model/Type | EES-WA-01 |
Automation Grade | Automatic |
Material | ABS |
Sensor | SUCTION DASED |
Weight | 20KG |
Size/Dimension | 300 |
Online Effluent Water Quality Monitoring Make: Enviro Empirical Model No: EES-WA-01
Parameters: · BOD · COD · TSS · PH
Specifications:
TSS (UV Based Probe) · Standard Range: 0-500 mg · Accuracy: +/- 5%
Ø Cod By Uv Correlation · Standard Range: 0-1000 Mg/L · Cod Accuracy: +/- 5%
Ø Bod By Uv Correlation · Standard Range: 0-1000 Mg/L Bod · Accuracy: +/- 2%
Ø Ph (ion Exchange) Standard Range: 0-14 Ph Accuracy: +/- 2%
Description: ü Supply:90-264 VAC, 50/60 Hz 40VA ü Screen: Color TFT LCD, ü Size:5.7" Resolution:320x240 Pixels, ü LED Backlight Resistive Touch Screen, ü Memory:5000 Lines of Measurements (upto16Channels) With Date & Time ü Enclosure: MS With Epoxy Coating, ü IP68 ü Automatic relay for sampling ü Sampling pump ü Wiper for sensor cleaning ü No dosing of acid required Battery (optional) ü Site calibration ü Surge protection ü Micro controller based circuit ü Voltage protection ü Real time data sampling ü Friendly interval ü Easy to install ü Rigid body ü Micro controller based circuit ü Durable sensors • RS485 output
|
Additional Information:
Approx. Rs 15,500 / PieceGet Latest Price
Product BrochureService Details:Model Name/Number | Tmag |
Brand | Enviro empirical |
Application Media | Water |
Usage/Application | Water |
Connection | Flange |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION
Type :
Integral Mounted (standard) Remote Mounted (on request)
Model
T-Mag Series (T-MAG-MS01)
1) Min. Media Conductivity
:
15μs/cm (for lower conductivity consult factory)
2) Signal Output :
4-20mA,RS485 and Pulse with adjustment count
3) Display :
4 digit for flow rate & 8 digit for totalised flow
4) Power supply :
90-260V AC,50hz (24vdc and 12 vdc on request)
5) Line size :
15NB to 600 NB(more than 600 NB consult to foctary)
6) Accuracy :
+/-0.5% of F.S. (For 20 to 100% Flow)
7) Repeatability :
+/-0.2% of reading
8) Ambient Temperature :
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max
9) Operating Pressure :
Up to 10kg/cm2(other : Please consult)
10) Transmitter enclosure
:
Die Cast Aluminium IP 66, flow Tube IP 68
11) Process connection :
ASA 150 Flanged, as per table 16.5
12) Electrode :
S-316L
13) Lining :
PTFE
14) Flanges :
M.S
15) Pipe :
SS-304
16) Material of housing :
M.S
Approx. Rs 3.5 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Color | White |
Usage/Application | ETP STP |
Packaging Size | Y |
Brand/Make | ENVIRO EMPIRICAL |
Model/Type | Y |
Automation Grade | Automatic |
Material | SS |
Sensor | SS |
Weight | 10 |
Size/Dimension | 10 |
Measuring Method |
Dual beam absorbance method ( UV254nm & 365nm) |
Measuring Way |
Immersion measurement |
Measured Parameters |
COD, BOD(TOC), TSS(Turbidity), Water Temperature |
Measuring Range |
COD: 3000mg/L, BOD: 1500mg/L(TOC: 1500mg/L), TSS: 3000mg/L(Turbidity: 3000NTU), water temperature: 50℃ |
Measuring Accuracy |
COD: < 5%; TOC: < 5%; Turbidity: < 3%; Water Temperature: 0 .2℃ |
Resolution |
COD: 0 .01 mg/L; TOC: 0.1mg/L; Turbidity: 0.1NTU; Water Temperature: 0.1℃ |
Cleaning system |
Automatic cleaning with cleaning brush |
Power Supply Voltage |
12±5%VDC, current: <50mA (without cleaning brush) |
Communication Methods |
RS485, Modbus protocol |
Protection level |
IP68, Maximum water depth in 10m |
Highest Bearing Pressure |
1bar |
Cable Length |
5 or 10 meters |
Overall Dimensions |
214mm×φ50mm |
Probe Weight |
665g |
Shell Material |
POM and 316L |
Additional Information:
Approx. Rs 3.8 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Brand | ENVIRO EMPIRICAL |
Material | Mild Steel |
COD measuring range | 0 TO 3000 |
BOD Measuring Range | 0 TO 3000 |
TSS measuring range | 0 TO 3000 |
Warm Up Time | 30 |
Maintenance Cycle | 1 |
Measurement Principle | Uv Correlation |
Online Effluent Water Quality Monitoring
Make: Enviro Empirical Model No: EES-WA-01
Parameters:
· BOD
· COD
· TSS
· PH
Specifications:
TSS (UV Based Probe)
· Standard Range: 0-500 mg
· Accuracy: +/- 5%
Ø Cod By Uv Correlation
· Standard Range: 0-1000 Mg/L
· CodAccuracy: +/- 5%
Ø Bod By Uv Correlation
· Standard Range: 0-1000 Mg/L Bod
· Accuracy: +/- 2%
Ø Ph (ion Exchange) Standard Range: 0-14 Ph Accuracy: +/- 2%
Additional Information:
Explore More Services
© Enviro Empirical Services. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited