Gyanpur, Sant Ravidas Nagar, Uttar Pradesh
GST No. 09CKTPP4976P1ZO
Approx. Rs 15,600 / PieceGet Latest Price
Product BrochureService Details:Material | Stainless Steel |
Usage/Application | Industrial |
Size | 4 - 6 Inch |
Display | Digital |
Country of Origin | Made in India |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Approx. Rs 3.5 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Brand | ENVIRO EMPIRICAL |
Usage/Application | ETP STP |
Material | Stainless Steel |
Phase | Single Phase |
COD measuring range | 1500 |
BOD Measuring Range | 1000 |
TSS measuring range | 1000 |
Warm Up Time | 5MIN |
Maintenance Cycle | 1MIN |
Measurement Principle | Ultraviolet-visible spectroscopy |
Online Effluent Water Quality Monitoring
Make: Enviro Empirical Model No: EES-WA-01
Parameters:
· BOD
· COD
· TSS
· PH
Specifications:
TSS (UV Based Probe)
· Standard Range: 0-500 mg
· Accuracy: +/- 5%
Ø Cod By Uv Correlation
· Standard Range: 0-1000 Mg/L
· CodAccuracy: +/- 5%
Ø Bod By Uv Correlation
· Standard Range: 0-1000 Mg/L Bod
· Accuracy: +/- 2%
Ø Ph (ion Exchange) Standard Range: 0-14 Ph Accuracy: +/- 2%
Additional Information:
Approx. Rs 17,500 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | ENVIRO EMPIRICAL |
Model Name/Number | EMAG-MS-01 |
Usage/Application | Industrial |
Size | 0.5 - 2 Inch |
Display | Digital |
Display Type | Integral |
Warranty | 1 Year |
Wide Measuring Range | 17 TO 170M3/HR |
Pipe Diameter | 25MM |
Country of Origin | Made in India |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Additional Information:
Approx. Rs 15,800 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Model Name/Number | EMAG-MS-01 |
Application Media | Water |
Brand | ENVIRO EMPIRICAL |
Usage/Application | Water |
Connection | FLANGE |
Display | Digital |
Flow Range | 17M3/HR |
Accuracy | 0.5% |
Flange Size | 25MM |
ELECTROMAGNETIC FLOW METER TECHNICAL SPECIFICATION |
|
Type : |
Integral Mounted (standard) Remote Mounted (on request) |
Model |
T-Mag Series (T-MAG-MS01) |
1) Min. Media Conductivity : |
15μs/cm (for lower conductivity consult factory) |
2) Signal Output : |
4-20mA,RS485 and Pulse with adjustment count |
3) Display : |
4 digit for flow rate & 8 digit for totalised flow |
4) Power supply : |
90-260V AC,50hz (24vdc and 12 vdc on request) |
5) Line size : |
15NB to 600 NB(more than 600 NB consult to foctary) |
6) Accuracy : |
+/-0.5% of F.S. (For 20 to 100% Flow) |
7) Repeatability : |
+/-0.2% of reading |
8) Ambient Temperature : |
0-50C, Teflon Lining 125C Max, Rubber Lining 90C Max |
9) Operating Pressure : |
Up to 10kg/cm2(other : Please consult) |
10) Transmitter enclosure : |
Die Cast Aluminium IP 66, flow Tube IP 68 |
11) Process connection : |
ASA 150 Flanged, as per table 16.5 |
12) Electrode : |
S-316L |
13) Lining : |
PTFE |
14) Flanges : |
M.S |
15) Pipe : |
SS-304 |
16) Material of housing : |
M.S |
Additional Information:
Approx. Rs 3.5 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Brand | ENVIR EMPIRICAL |
Usage/Application | ETP STP |
Material | Stainless Steel |
Phase | Single Phase |
Color | White |
Automation Type | Automatic |
Country of Origin | Made in India |
Online Effluent Water Quality Monitoring With CPCB Connectivity.
Make: EES Model No: EES-WA-01
Parameters:
· BOD
· COD
· TSS
· PH
Specifications:
TSS (UV Based Probe)
· Standard Range: 0-500mg/l
· Accuracy: +/- 2%
Ø Cod By Uv Correlation
· Standard Range: 0-1000 Mg/L
· CodAccuracy: +/- 2%
Ø Bod By Uv Correlation
· Standard Range: 0-500 Mg/L Bod
· Accuracy: +/- 2%
Ø Ph (ion Exchange) Standard Range: 0-14 Ph Accuracy: +/- 2%
Description:
ü Supply:90-264 VAC, 50/60 Hz 40VA
ü Screen: Color TFT LCD,
ü Size:5.7" Resolution:320x240 Pixels,
ü LED Backlight Resistive Touch Screen,
ü Memory:5000 Lines of Measurements (upto16Channels)With Date & Time
ü Enclosure: Stainless Steel With Epoxy Coating,
ü IP68
ü Automatic relay for sampling
ü Sampling pump
ü Wiper for sensor cleaning
ü No dosing of acid required
Battery (optional)
ü Site calibration
ü Surge protection
ü Micro controller based circuit
ü Voltage protection
ü Real time data sampling
ü Friendly interval
ü Easy to install
ü Rigid body
ü Micro controller based circuit
ü Durable sensors
• RS485 output
Additional Information:
Approx. Rs 35,000 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Type Of Ph Meter | Portable |
Brand | ENVIRO EMPIRICAL |
Usage/Application | Industrial |
Weight | 1.5KG |
Calibration | 2 POINT |
Model Name/Number | S7010 |
We are engaged in offering a wide range of Ph And Orp Meter to our clients. Our range of all products is widely appreciated by our clients.
Approx. Rs 3.5 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial Use |
Dimensions | na |
Brand | ENVIRO EMPIRICAL |
Model Name/Number | EES-WA-01 |
Color | white |
Resolution | 0.01 |
Power Supply | 220v ac |
Type | touch online |
Maintenance Interval | 30sec |
Measuring Time | 10sec |
Measuring Method | Dual beam absorbance method ( UV254nm & 365nm) |
Measuring Way | Immersion measurement |
Measured Parameters | COD, BOD(TOC), TSS(Turbidity), Water Temperature |
Measuring Range | COD: 3000mg/L, BOD: 1500mg/L(TOC: 1500mg/L), TSS: 3000mg/L(Turbidity: 3000NTU), water temperature: 50℃ |
Measuring Accuracy | COD: < 5%; TOC: < 5%; Turbidity: < 3%; Water Temperature: 0 .2℃ |
Resolution | COD: 0 .01 mg/L; TOC: 0.1mg/L; Turbidity: 0.1NTU; Water Temperature: 0.1℃ |
Cleaning system | Automatic cleaning with cleaning brush |
Power Supply Voltage | 12±5%VDC, current: <50mA (without cleaning brush) |
Communication Methods | RS485, Modbus protocol |
Protection level | IP68, Maximum water depth in 10m |
Highest Bearing Pressure | 1bar |
Cable Length | 5 or 10 meters |
Overall Dimensions | 214mm×φ50mm |
Probe Weight | 665g |
Shell Material | POM and 316L |
Additional Information:
Approx. Rs 3.5 Lakh / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Brand | ENVIRO EMPIRICAL |
Usage/Application | ETP STP |
Material | Stainless Steel |
COD measuring range | 3000 |
BOD Measuring Range | 1500 |
TSS measuring range | 3000 |
Warm Up Time | 30SEC |
Maintenance Cycle | 1 |
Measurement Principle | Measuring Method Dual beam absorbance method ( UV254nm & 365nm) |
Measuring Method |
Dual beam absorbance method ( UV254nm & 365nm) |
Measuring Way |
Immersion measurement |
Measured Parameters |
COD, BOD(TOC), TSS(Turbidity), Water Temperature |
Measuring Range |
COD: 3000mg/L, BOD: 1500mg/L(TOC: 1500mg/L), TSS: 3000mg/L(Turbidity: 3000NTU), water temperature: 50℃ |
Measuring Accuracy |
COD: < 5%; TOC: < 5%; Turbidity: < 3%; Water Temperature: 0 .2℃ |
Resolution |
COD: 0 .01 mg/L; TOC: 0.1mg/L; Turbidity: 0.1NTU; Water Temperature: 0.1℃ |
Cleaning system |
Automatic cleaning with cleaning brush |
Power Supply Voltage |
12±5%VDC, current: <50mA (without cleaning brush) |
Communication Methods |
RS485, Modbus protocol |
Protection level |
IP68, Maximum water depth in 10m |
Highest Bearing Pressure |
1bar |
Cable Length |
5 or 10 meters |
Overall Dimensions |
214mm×φ50mm |
Probe Weight |
665g |
Shell Material |
POM and 316L |
Additional Information:
Approx. Rs 35,000 / PieceGet Latest Price
Product BrochureService Details:Minimum Order Quantity | 1 Piece |
Model Name/Number | S7010 |
Brand | ENVIRO EMPIRICAL |
Usage/Application | Industrial |
Weight | 1.5KG |
Calibration | 2 POINT |
Resolution | 0.1 |
Display Type | LCD |
Ph Range | 0 TO 14PH |
Country of Origin | Made in India |
Additional Information:
Explore More Services
© Enviro Empirical Services. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited